Federal regulators continue to recognize value of clinical laboratory testing in near-patient settings

To help in the diagnosis and management of two sexually-transmitted diseases, another point-of-care diagnostic test will soon be available for use in physician’s offices, urgent care clinics, and other healthcare settings. The federal Food and Drug Administration (FDA) announced it granted a CLIA waiver for the binx health io CT/NG assay, a molecular platform used to detect sexually transmitted diseases—chlamydia and gonorrhea—at the point of care (POC).

In a press release, the FDA announced it was “granting a waiver under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) for the binx health io CT/NG assay [binx io],” and that “it is allowing the use of the binx health io CT/NG assay at point-of-care settings, such as in physician offices, community-based clinics, urgent care settings, outpatient healthcare facilities, and other patient care settings, operating under a CLIA Certificate of Waiver, Certificate of Compliance, or Certificate of Accreditation.”

This will be welcome news to many medical professionals, as it indicates federal regulators recognize the value of diagnostic testing in near-patient settings.

Allows Non-Laboratorian Processing at Point of Care

In 2019, binx health received FDA 510k clearance to market its binx io rapid point-of-care (POC) platform for women’s health. “The binx io platform is a rapid, qualitative, fully-automated test, designed to be easy to use, and intended for use in POC or clinical laboratory settings … In the company’s recently completed 1,523-person, multi-center clinical study, 96% of patient samples were processed on the binx io by non-laboratorians in a POC setting,” a binx press release noted.

binx-health-io-platform
According to the Boston-based biotech company’s website, the binx io platform (above) combines ultra-rapid, polymerase chain reaction (PCR) amplification with binx health’s proprietary and highly sensitive electrochemical detection technology. The io instrument processes a single-use, CT/NG cartridge that contains all reagents for testing self- or clinician-collected vaginal swabs and male urine samples. No sample preparation is required. Test results are available in less than 30 minutes. (Photo copyright: binx health.)

“With ever-increasing sexually transmitted infection rates, point-of-care and CLIA-waived platforms like the binx io are essential additions to our sexually-transmitted-infection-control toolbox, which will increase accessibility and decrease the burden on traditional healthcare settings,” Barbara Van Der Pol, PhD, Professor of Medicine and Public Health at University of Alabama at Birmingham, said in a binx press release.

According to binx, the Centers for Disease Control and Prevention (CDC) estimates that one in five people in the US has a sexually-transmitted disease (STD), with an estimated 108 million Americans potentially in need of routine STD testing. Additionally, chlamydia and gonorrhea are the two most treated STDs globally.

Study Finds Binx Health POC Assay Comparable to Traditional Clinical Laboratory NAATs

Van Der Pol led a team of researchers who compared the binx io chlamydia/gonorrhea POC assay to three commercially-available nucleic acid amplification tests (NAATs). The binx-funded study, published in JAMA Network Open, analyzed swab samples from 1,523 women (53.6% with symptoms) and urine samples from 922 men (33.4% symptomatic) who presented to 11 clinics in nine cities across the US.

The molecular point-of-care assay proved on par with laboratory-based molecular diagnostics for vaginal swab samples, while male urine samples were associated with “good performance.”

For chlamydia:

  • Sensitivity of the new POC assay was 96.1% (95% CI, 91.2%-98.3%) for women and 92.5% (95% CI, 86.4%-96.0%) for men.
  • Specificity of the new POC assay was 99.1% (95% CI, 98.4%-99.5%) for women and 99.3% (95% CI, 98.4%-99.7%) for men.

For gonorrhea:

  • Sensitivity estimates were 100.0% (95% CI, 92.1%-100.0%) for women and 97.3% (95% CI, 90.7%-99.3%) for men.
  • Specificity estimates were 99.9% (95% CI, 99.5%-100%) for women and 100% (95% CI, 95.5%-100%) for men.

Van Der Pol told Reuters News, “The bottom line is that chlamydia and gonorrhea are still the most frequently reported notifiable diseases in the US, and it costs us in the $5 billion to $6 billion range to manage the consequences of untreated infections. Unfortunately, about 70% of women who are infected don’t have any symptoms, so they don’t know they need to be tested.”

Tim-Stenzel-MD-PhD-FDA
“The ability to diagnose at a point-of-care setting will help with more quickly and appropriately treating sexually-transmitted infections, which is a major milestone in helping patients,” said Tim Stenzel, MD, PhD (above), Director of the Office of In Vitro Diagnostics and Radiological Health at the FDA’s Center for Devices and Radiological Health, in the FDA announcement. “More convenient testing with quicker results can help patients get access to the most appropriate treatment. According to the CDC, one in five Americans are diagnosed with sexually-transmitted infections every year, which is why access to faster diagnostic results and faster, more appropriate treatments will make significant strides in combatting these infections,” he added. As point-of-care testing for specific diseases increases, clinical laboratories that process these tests may see a decrease in specimen processing orders. (Photo copyright: Duke University.)

The CLIA waiver allows binx to distribute the chlamydia/gonorrhea test to 220,000 CLIA-waived locations across the US through the company’s national commercial distribution partnership with McKesson. Obstetrician/gynecologist and primary care offices, urgent care facilities, community health clinics, STD clinics, and retail settings are all potential testing sites.

Binx says its testing platform can improve health outcomes by:

  • Increasing treatment compliance,
  • Limiting onward transmission,
  • Minimizing the risk of untreated conditions, and
  • Ensuring the right treatment is provided.

In the binx health press release, binx CEO Jeffrey Luber, JD, said, “The io instrument’s demonstrated clinical effectiveness, ease of operation, and patient convenience make it a much-needed tool with transformative implications for public health, especially now during the COVID-19 pandemic, where STI [sexually-transmitted infection] prevention services nationwide have been dramatically reduced or cut altogether as resources have been allocated to focus on the COVID response.”

Should Clinical Laboratories Be Concerned about POCT?

It happens often: after consulting with his or her doctor, a patient visits a clinical laboratory and leaves a specimen. The test results arrive at the doctor’s office in a few days, but the patient never returns for treatment. That is why point-of-care tests (POCTs) came to be developed in the first place. With the patient in the clinic, a positive test result means treatment can begin immediately.

As the US healthcare system continues toward more integration of care and reimbursement based on value, rather than fee-for-service, point-of-care testing enables physicians and other healthcare providers to diagnose, test, and prescribe treatment all in one visit.

Thus, it is a positive step for healthcare providers. However, clinical laboratories may view the FDA’s increasing endorsement of waived point-of-care testing as a trend that is unfavorable because it diverts specimens away from central laboratories.

There also are critics within the medical laboratory profession who point out that waived tests—often performed by individuals with little or no training in laboratory medicine—have much greater potential for an inaccurate or unreliable result, when compared to the same assay run in a complex, CLIA-certified clinical laboratory.

Andrea Downing Peck

Related Information:

FDA Allows for First Point-of-Care Chlamydia and Gonorrhea Test to be Used in More Near Patient-Care Settings

Binx Health Receives FDA CLIA Waiver for Chlamydia and Gonorrhea Test, Expanding Critical Access to Single-Visit Diagnoses

Binx Health Receives FDA 510(k) Clearance for Rapid Point of Care Platform for Women’s Health

POC Test for Chlamydia, Gonorrhea as Good as Lab-Based Assays

Evaluation of the Performance of a Point-of-Care Test for Chlamydia and Gonorrhea

Rapid HIV Tests Suitable for Use in Non-Clinical Settings (CLIA Waived)

;